For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.LA
0

How is the measuring tape used correctly?

05/03/y 11:13:39

Have you ever wondered how to accurately measure the slope, inclination and angle of a building while still ensuring aesthetics? With the water level widely used in architecture and interior design, it has become an indispensable tool in every measurement stage. Based on practical experience and a deep understanding of customer needs, the following article will share how to use the water level correctly, helping to overcome common difficulties when measuring.

Overview of spirit level

The level is known by other names such as level, livo or balance, which can be seen a lot in the mechanical field. This tool helps to check the inclination, slope and deviation angles on many types of works, from construction to interior and exterior design. 

In the activities of measuring and checking deviation angles at works or during interior construction, people often prefer to use level bars (or straight level) and electronic level (also known as electronic angle measuring ruler). In particular, the line of electronic level rulers integrated with laser is always chosen by many technicians and acceptance teams thanks to its outstanding accuracy and convenience.

How to use a spirit level correctly

Since the level rod is the most commonly used type, in this guide, EMIN will focus on how to use a straight level. For other types of levels such as frame levels or electronic levels, the principles of use are similar. 

Step 1: Place the level rod on the surface to be measured. If the surface is not flat, the glass tube on the ruler will have one end higher, causing the air bubble to move towards the high end. 

Step 2: Observe the graduations on the ruler body to determine the difference between the two ends. 

Step 3: Read the incline measurement result based on the position of the air bubble relative to the graduations.

How to read a water level correctly

When measuring flatness with a spirit level, people usually gradually adjust by inserting the feeler into the gap, continuing to adjust until the air bubble is almost balanced in the middle of the spirit level tube. Then, the deviation result will be determined based on the thickness of the feeler used. 

If you want to calculate more accurately, you can apply the following method: 

1. Calculate the relative tilt: Assuming the level ruler is 500mm long and has a sensitivity of 0.02mm/m, we calculate as follows: 

- 0.02 x 2 = 0.04mm, meaning that in 1 meter, the difference between the two edges will be 0.04mm. 

2. Calculate the absolute tilt: 

- 0.04 x 0.5 = 0.02mm, meaning that the actual difference on a 500mm long ruler will be 0.02mm.

Refer to the products of the Water ruler at: https://emin.vn/thiet-bi-do-co-khi-nivo-level-do-goc-va-do-thang-nivo-level-thuoc-thuy-155/pc.html?srsltid=AfmBOoqR-zDnFyDicCJ-Pp0urdu9KKsE10LJ7KFa21ZsoR0NBHA6_t8u 

Notes when using a spirit level to ensure durability and accuracy

- Each type of level has a different design, so always read the accompanying instructions carefully to ensure correct operation, avoiding errors that affect the accuracy of the device.

- Avoid dropping the level on a hard surface, as strong impact can damage the water tube or affect the accuracy of the measurement.

- Although some models are water-resistant, you should still limit water contact with the level, especially the electronic components inside.

- If using an electronic level, turn it off when not in use to save battery. If not used for a long time, remove the battery to avoid leakage and damage.


- After each use, clean the level, store in a dry, cool place, avoid areas with high temperature and humidity to prolong the life of the device.


Hopefully with the above notes, you will use the level correctly and achieve the desired accurate measurement results.

ຂ່າວທີ່ກ່ຽວຂ້ອງ

Storing insulin at the wrong temperature: the medication becomes ineffective, yet it’s impossible to tell by looking at it
19/11/y 10:00:13

When insulin and other biological products are stored outside the recommended temperature range (2°C to 8°C for unopened products), their protein structures become denatured, leading to a reduction or complete loss of therapeutic activity. In many cases, the medication may be compromised without showing any visible signs, posing a risk of difficult-to-control hyperglycemia and constituting a violation of pharmaceutical storage standards

How to Choose the Right Welding Machine Power Capacity
18/11/y 11:06:42

Welding machine power describes the electrical input required to create and sustain an arc. Choose it by checking the available supply, welding process, duty cycle, material thickness, and expected operating time.

What Is a Three-Phase Welding Machine and How to Choose One?
18/11/y 11:01:18

A three-phase welding machine typically uses 380V industrial power and suits workshops that need stable operation for heavier or recurring welding work. Choose the process, capacity, input supply, and working intensity together.

Purchase genuine Associated Research (ARI) equipment at EMIN, with a 5-year warranty
18/11/y 09:19:46

Since September 2021, EMIN has served as the official distributor in Vietnam for brands under the Ikonix umbrella, including Associated Research. You now have a local point of contact for expert product selection advice, price quotations, and after-sales support eliminating the need to navigate the complexities of sourcing equipment independently. All genuine products come with a manufacturer’s warranty of up to 5 years, subject to the manufacturer’s terms and conditions

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ