For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.LA
0

Reliability Test for Relay Using GW PSW Power Supply and PEL-3111 E. Load

19/12/y 17:28:24

How do you conduct relay connection point (N.O. / N.C.) tests? How do you test the life cycle of relay’s connection point (N.O. / N.C.)?   How do you evalua

How do you conduct relay connection point (N.O. / N.C.) tests? How do you test the life cycle of relay’s connection
point (N.O. / N.C.)?   How do you evaluate the connection resistance of connection point (N.O. / N.C.) after multiple
tests? How do you evaluate the speed for operating connection point (N.O. / N.C.)? 

Relay, functioning to produce mechanical on-off movement by receiving electric signal to change electro magnet,
is often applied to control other electronic device via receiving electronic signal. Voltage exerted on relay’s coil
allows current to pass through coil and magnetizes core. Armature is then be pulled by core due to electromagnetic
force. Hence, a mechanical on-off movement is produced.  


As shown on the top diagram, PSW 30-108, Relay and PEL-3111 are connected by series. PEL-3111 is set to 80A
current sink. Each time, Relay’s NO-COM is closed, NO-COM is tested for its current reliability. In the meantime,
PSW 80-40.5 is utilized to output sequential power supply to produce control signal to control Relay’s NO-COM.

One GW Instek PSW 80-40.5 can meet the actual measurement requirements via planning Relay’s control signal.
It not only controls signal’s voltage, current, time and period, but also determines the number of operating cycle.
There are totally 20,000 steps and each step can be set from 50ms to 20 days. The number of cycle can reach
1 billion or infinite by different specifications. Relay’s control signal can only verify the mechanical characteristics
of NO-COM and NC-COM. For further electric characteristic verification of NO-COM and NC-COM, PSW 30-108
and PEL-3111 must be concurrently utilized to produce C.C. output. Based upon Relay’s specifications, the combined
application of two instruments can conduct fast current switching test and provide large current verification,
including current withstanding value and current withstanding time so as to ensure Relay’s quality. 

GW instek PEL-3111 Programmable DC Electronic Load (150V, 210A, 1050W)

ຂ່າວທີ່ກ່ຽວຂ້ອງ

What Is a VLF Very Low Frequency AC Voltage Tester ?
26/08/y 11:02:45

A VLF very low frequency AC voltage tester is used to assess the insulation condition of cables, transformers, and certain high-voltage electrical equipment. The equipment generates AC test voltage at a very low frequency, typically in the range of 0.05 Hz to 0.1 Hz as referenced in technical sources. This method is particularly useful for testing capacitive loads, such as power cables and certain high-voltage equipment.

Effective Transformer Winding Testing with a DC Resistance Tester
26/08/y 11:00:27

A DC resistance tester is used to measure the resistance of transformer windings, helping evaluate the condition of connections, contact points, and winding stability. Measurement results can be affected by winding temperature, test current, and the actual condition of the contact points.

Insulation Oil Quality Testing for Electrical Equipment
26/08/y 10:59:41

Insulation oil testing helps detect changes associated with aging, moisture, and contaminants in the oil. Combining a suitable insulation oil tester with careful sampling procedures and regular data monitoring supports proactive maintenance of electrical equipment and helps maintain the required insulation condition during operation.