In many technical systems—from server rooms to residential HVAC spaces—temperature and humidity monitoring is often carried out in a very simple way: placing a measuring device in the room and reading the displayed values. However, significant variations can still exist across different areas without anyone noticing.

From Point Measurement to Microclimate mapping

Air within an enclosed space is not distributed as uniformly as pepople assume. It is entirely normal for temperature and humidity readings to vary across different locations when using a thermo-hygrometer, especially in air-conditioned environments.

Control environmental goes beyond simply knowing the temperature or humidity level it focuses on understanding how these parameters are distributed throughout the entire space. In a technical room, measurements should be taken at a minimum of 3–5 locations, such as near the entrance, close to the air conditioning outlet, near equipment, at the center of the room, and in corners.

From there, the average value can be used to assess overall conditions, while the maximum and minimum values help identify potential risk zones.

Proper Placement of Thermo-Hygrometers

In many cases, temperature and humidity meters function perfectly, yet the readings fail to reflect actual environmental conditions. The issue often lies in how the device is installed and used.

Recommended placement guidelines:

  • Height of approximately 1.1–1.5 meters (typical breathing or operating zone)

  • At least 0.5 meters away from walls

  • Avoid direct exposure to air conditioning airflow

  • Keep away from heat sources (machinery, direct sunlight)

A sensor placed directly under an air conditioning airflow will quickly register a lower temperature than the actual room average. When positioned too close to a wall, readings can be affected by the wall’s thermal and moisture retention properties. Even placing the device near a doorway can cause short-term fluctuations each time the door is opened.

Importantly, these deviations are not easily perceived by human senses. While people may not distinguish between 60% and 70% relative humidity, for sensitive equipment and materials, this difference is significant.

A Continuously Changing Environment

Another often overlooked factor is time. Temperature and humidity are not static values they fluctuate based on air conditioning cycles, occupancy levels, and even the time of day.

A single measurement taken in the morning can different from one taken in the afternoon, when systems have been running continuously and thermal loads have increased. As a result, relying on a one-time measurement often leads to incomplete or inaccurate conclusions.

In environments that require high stability such as server rooms or equipment storage areas monitoring is not just about measurement, but about continuous tracking to understand trends over time rather than relying on a single data point.

This is where temperature and humidity data loggers become essential. They provide continuous measurement, data storage, and real-time analysis, enabling more accurate and proactive environmental control.

ຂ່າວທີ່ກ່ຽວຂ້ອງ

Storing insulin at the wrong temperature: the medication becomes ineffective, yet it’s impossible to tell by looking at it
19/11/y 10:00:13

When insulin and other biological products are stored outside the recommended temperature range (2°C to 8°C for unopened products), their protein structures become denatured, leading to a reduction or complete loss of therapeutic activity. In many cases, the medication may be compromised without showing any visible signs, posing a risk of difficult-to-control hyperglycemia and constituting a violation of pharmaceutical storage standards

Purchase genuine Associated Research (ARI) equipment at EMIN, with a 5-year warranty
18/11/y 09:19:46

Since September 2021, EMIN has served as the official distributor in Vietnam for brands under the Ikonix umbrella, including Associated Research. You now have a local point of contact for expert product selection advice, price quotations, and after-sales support eliminating the need to navigate the complexities of sourcing equipment independently. All genuine products come with a manufacturer’s warranty of up to 5 years, subject to the manufacturer’s terms and conditions

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ