For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.LA
0
Product image

Trig-Tek Inc. 203G8-08 Charge Amplifier (60kHz/ 70kHz/ 80kHz (low); 20kHz/ 25kHz/ 30kHz (high))

ຕິດຕໍ່
ການຊຳລະເງິນທີ່ປອດໄພ
ການຮັບປະກັນຄຸນນະພາບ
ປ່ຽນ ແລະ ສົ່ງຄືນງ່າຍ
ມີບໍລິການຈັດສົ່ງ

Low Pass Filter: 

+ Frequencies: 60kHz/ 70kHz/ 80kHz

+ Tolerance: -

High Pass Filter: 

+ Frequencies: 20kHz/ 25kHz/ 30kHz

+ Tolerance: 5%


Input

Charge Sensitivity: 1 to 110 pC/g with two selectable ranges (1–11 and 10–110 pC/g) with continuous adjustment.

Frequency Response: ±2% from 5 Hz to 30,000 Hz referred to 100 Hz.

Overload Recovery: ≤15,000 pC, 1 ms half-sine input pulse causes no effect except clipping.

Amplitude Stability vs Input Capacity: <0.1% change per 1000 pF.

Amplitude Stability vs Temperature: <3% change from 30° to 130°F.

Shunt Resistance: Operates with input impedance above 100 kΩ.

Acceleration Output (NOR)

Voltage (max): 10 Vrms.

Sensitivity: 100 mVrms/Pk g.

Impedance: <50 Ω (10 mA max).

Amplitude Linearity: ±1% best straight-line approximation.

Amplitude Accuracy: ±2% of reading ±1% FS with selected low-pass filter.

Noise: 0.05 pC max with 1.0 pC/g sensitivity; increases 0.006 g/1000 pF added capacitance.

Harmonic Distortion: <1%.

DC Offset: <5 mV.


Velocity Output

Voltage (max): 10 Vrms.

Sensitivity: 354 mVrms/Pk ips.

Impedance: <50 Ω (10 mA max).

Amplitude Accuracy vs Frequency: ±3% from 25 Hz to 3000 Hz (–6 dB/oct) with LPF.

DC Offset: <5 mV.


Displacement Output

Level: 0–10 Vrms.

Sensitivity: 10 mVrms/mil Pk-Pk.

Impedance: <50 Ω (10 mA max).

Amplitude Accuracy (30–1000 Hz): ±4% (–12 dB/oct).

Amplitude Accuracy (25–3000 Hz): ±5% (–12 dB/oct) with LPF.

DC Offset: <5 mV.


FS AC Output (Tape Output)

Level: 0.5 to 1.5 Vrms for selected meter FS.

Impedance: <50 Ω (10 mA max).

Frequency Response: Acceleration: ±3%.; Velocity: ±4%.; Displacement: ±5%.

Linearity: ±1% FS.

DC Offset: <4 mV.


FS DC Output

Impedance: <50 Ω (10 mA max).

Sensitivity: 10 V for selected full-scale meter range.

Linearity: ±1% FS.

Amplitude Accuracy: Acceleration: ±2% reading ±1% FS.; Velocity: ±4% reading ±1% FS.; Displacement: ±5% reading ±1% FS.

Dynamic Range (Acceleration): 50 dB below FS.


Power: 115 or 203 Vrms, 50–400 Hz, 110 V nominal.


Controls: 

Cal-Oper Switch: Selects Calibrate input or Accel input.

pC/g – mV/g Switch: Selects charge input or voltage input accelerometers.

Sensitivity Switch: Selects X1 or X10.

Sensitivity Dial: Adjusts 1–11 for selected range.

High-Pass Filter Switch: 20 Hz, 110 Hz, 300 Hz (48 dB/oct).

Low-Pass Filter Switch: 300 Hz, 2 kHz, 10 kHz (48 dB/oct).

Units Switch: Selects Pk g, Pk ips, or DA MILS.

FS Switch: Selects 1, 3, 10, 30, or 100 full-scale units.

Alarm Set Switch: Monitors or resets alarm.

SE-DIFF Switch: Selects Single-Ended or Differential input.

In-Out Filter Switch: Inserts LPF in series with input (pC/g mode only).


Indicators

Panel Meter: 3.5-digit reading of selected units.

OL Light: Overload indicator.

Cal Light: Indicates calibration mode.

Alarm Light: Indicates preset alarm exceeded.


Mechanical

Size: 7" H × 2.7" W × 13" D (17.8 × 6.9 × 33.0 cm).

Up to six modules fit into a 19" rack

Datasheet


ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ