For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.LA
0

The Latest Series of Industrial Acoustic Imaging Cameras from Fluke

16/10/y 15:57:21

The latest line of acoustic imagers from Fluke offers a more intuitive solution for detecting air leaks and mechanical problems. Models ii915, ii905, and ii500 easily identify problems by "seeing" the sound. Thanks to modern technology, the inspection process becomes faster and obtains more relative results, saving time and repair costs.

Fluke ii915 – Specializes in Detecting Compressed Air and Vacuum Leaks

The Fluke ii915 is intended for detecting compressed air and vacuum leaks in industrial environments. With more than 100 ultra-sensitive microphones, this device can operate effectively even in noisy environments where conventional methods find it difficult to detect leaks. 

Fluke ii915

The special feature of ii915 is the ability to display the source of leaks on the screen with visual images, helping you not only detect but also determine the exact location of the problem, helping to reduce inspection time and at the same time Optimize energy efficiency for the plant, minimize compressed air loss and ensure operating processes are always highly efficient. If you are having problems with energy loss in your compressed air system, the Fluke ii915 will definitely be the right choice for you to handle your work tasks.

Fluke ii905 – Remote Local Discharge Detection

When it comes to safety testing of high-voltage electrical systems, the Fluke ii905 is definitely a must-have. Specially designed for remote corona and arc discharge detection

Fluke ii905

Rapid partial discharge detection can prevent equipment damage and ensure the safety of substations and power lines, minimizing risky situations that could lead to downtime or failure. big. With remote detection capabilities, the Fluke ii905 allows you to inspect without getting too close to the equipment, minimizing operator safety risks.

Fluke ii500 – Versatile Device, Comprehensive Solution

If you are looking for a comprehensive solution for both gas leak detection and electrical problems, the Fluke ii500 is the best choice. This device combines both of the above features in a single device, bringing convenience and high efficiency to industrial equipment maintenance activities. 

Fluke ii500

The Fluke ii500 is quite easy to use, not only that, it can also store and analyze images and videos to help you monitor and report problems in detail. This makes maintenance easier, thereby minimizing downtime and optimizing production processes. Suitable for manufacturing plants, especially those that need flexibility in testing and maintaining many different systems.

Practical applications:

Manufacturing Industry & Manufacturing Plants

In manufacturing environments, problems such as compressed air leaks often lead to significant energy waste. Fluke ii915 can solve this problem. Factories often face the problem of energy consumption from compressed air systems that are not properly maintained, causing significant losses in operating costs. With the ability to detect even in noisy environments, the ii915 ensures quick inspections, helping to optimize energy efficiency and minimize downtime for maintenance.

Electrical technology and transformer stations

The Fluke ii905 is especially useful for testing substations, high voltage power lines and power distribution systems. Partial discharge phenomena such as corona or arcing can cause serious problems in the safety and durability of electrical equipment in general. Instead of waiting until a major incident occurs, using ii905 to detect electrical discharges early helps minimize the risk of fire, explosion, equipment damage and prolongs system life. Thanks to remote detection capabilities, technicians do not need to come into direct contact with high-voltage electrical equipment, thereby minimizing safety risks.

HVAC System Maintenance (Heating, Ventilation and Air Conditioning)

In HVAC systems, problems with air leaks or mechanical damage can affect performance and operating costs. The Fluke ii500 can help detect these problems early, thereby minimizing energy loss and extending the life of the system. Early leak detection helps ensure optimal system operation, especially in large commercial buildings or manufacturing environments where HVAC systems play a critical role in maintaining temperature and air quality. gas.

Why Choose an Acoustic Camera Instead of Traditional Methods

Detecting leaks or mechanical problems with acoustic cameras is Fluke's breakthrough innovation in industrial inspection. Compared to traditional methods, "seeing" the sound allows you to identify problems more quickly, minimizing manual inspection time. Fluke II-Series devices make accurate decisions on the spot, thanks to Wi-Fi connectivity and data synchronization with the Fluke Connect platform. From there, sharing data with colleagues or storing it for later reference also becomes easier.

[MINI GAME] FLUKE LAUNCHES NEW PRODUCT - FLUKE LAUNCHES NEW PRODUCT, SHARE NOW TO RECEIVE GIFTS INSTANTLY

To thank customers for their support recently, EMIN&Fluke is having a small minigame for 10 lucky people to have the opportunity to immediately receive cool COOLMATE t-shirts!

How to participate:

Step 1: LIKE this post and EMIN VietNam fanpage

Step 2: SHARE the article in public mode

Step 3: COMMENT with the hashtag #AcousticImagerEMINxFLUKE to participate in Lucky Draw and have a chance to receive a cool COOLMATE t-shirt from us

Event time: From October 18, 2024 to December 24, 2024.

The winning list will be announced on December 25, 2024 in the comments section of this article.

Note: Only 10 lucky people will be randomly selected and announced on December 25, 2024!

Hurry and join now to have the opportunity to receive gifts and discover the most advanced solutions from Fluke!

ຂ່າວທີ່ກ່ຽວຂ້ອງ

What Is Resonant Frequency? Why Can a Single Frequency Range Damage the Entire Product?
10/07/y 15:10:46

A device may operate stably for months, yet suffer cracks, broken solder joints, or snapped component leads after being transported. What surprises many engineers is that the vibration amplitude during transport is no greater than usual. The root cause lies in a specific frequency range where the product's structure absorbs energy most intensely, triggering resonance and causing continuous stress concentration at a single point.

Should Carton Packaging Undergo Vibration Testing or Drop Testing First?
10/07/y 10:38:40

Một kiện hàng gần như không bao giờ bị rơi ngay khi vừa rời khỏi nhà máy. Quãng đường hàng trăm kilomet trên xe tải, container hay băng chuyền mới là giai đoạn diễn ra đầu tiên, nơi bao bì liên tục chịu rung lắc trong nhiều giờ. Chỉ sau đó mới đến những cú va chạm khi bốc xếp, giao nhận hoặc rơi ngoài ý muốn.

Distinguishing Between DFT and WFT in Coating Thickness Measurement
09/07/y 14:40:30

Many projects encounter a situation where a freshly applied coating looks perfectly uniform and paint consumption matches the estimate, yet additional coating is required during inspection because the thickness is insufficient. This leads many to suspect measurement errors or equipment inaccuracy, whereas the actual cause is a confusion between WFT (Wet Film Thickness) and DFT (Dry Film Thickness)

Can a car paint thickness gauge detect if a vehicle has been in a collision?
08/07/y 16:56:01

Many used car buyers often spend a considerable amount of time examining the paintwork, the gaps between body panels, or the overall condition of the exterior. However, these signs can be skillfully masked following repairs; precise color matching and careful polishing can make the vehicle appear almost factory-original.

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ