Flue gas CO (with H₂-compensation)

Measuring range: 0 to 8000 ppm

Accuracy:

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 8000 ppm)

Resolution: 1 ppm

Reaction time t₉₀: < 40 s


Flue gas COlow

Measuring range: 0 to 500 ppm

Accuracy:

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 500 ppm)

Resolution: 0.1 ppm

Reaction time t₉₀: < 40 s


Flue gas Draught

Measuring range: -9.99 to +40 hPa

Accuracy

±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution: 0.01 hPa with fine draught option 0.001 hPa


Temperature

Measuring range: -40 to +1200 °C

Accuracy:

±0.5 °C (0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution:

0.1 °C (-40 to +999.9 °C)

1 °C (> +1000 °C)


Flue gas degree of effectivity, Eta (calculated)

Measuring range: 0 to 120 %

Resolution: 0.1 %

Flue gas loss (calculated)

Measuring range: 0 to 99.9 %

Resolution: 0.1 %


Flue gas CO₂ calculation (calculated from O₂)

Measuring range: Display range 0 to CO₂ max

Accuracy: ±0.2 Vol.%

Resolution: 0.1 Vol.%


Pressure measurement

Measuring range: 0 to +300 hPa

Accuracy:

±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution: 0.1 hPa with fine draught option 0.01 hPa


Flue gas CO (without H₂-compensation)

Measuring range: 0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution: 1 ppm


Ambient CO

Measuring range: 0 to 500 ppm

Accuracy:

±5 ppm (0 to 100 ppm)

±5 % of mv (> 100 ppm)

Resolution: 1 ppm

with CO probe 0632 3331


Ambient CO₂

Measuring range:

0 to 1 Vol.%

0 to 10000 ppm

Accuracy:

±75 ppm or ±3 % of mv (0 to 5000 ppm)

±150 ppm or ±5 % of mv (5001 to 10000 ppm)

with ambient CO₂ probe 0632 1240


Gas leak measurement for combustible gases (via gas leak detection probe)

Measuring range: 0 to 10000 ppm CH₄ / C₃H₈; Display range

Accuracy: Signal optical display (LED) audible signal via buzzer

Reaction time t₉₀: < 2 s

with gas leak detection probe 0632 3330


General technical data

Dimensions: 240 x 85 x 65 mm

Operating temperature: -5 to +45 °C

Display size: 240 x 320 pixels

Display function: Colour graphic display

Power supply: Battery: 3.7 V / 2,400 mAh; Mains unit: 6 V / 1.2 A

Maximum memory: 500 Measurement values

Storage temperature: -20 to +50 °C

Weight: 573 g


Set with flue gas analyzer testo 320 (with O2, CO measurement cell), compact 300 mm flue gas probe, Spare dirt filters, adpater, transport case and mains unit