For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.LA
0

Test Script Applications -Solving Complex Test Patterns

12/04/y 11:45:05

The uniqueness of GW Instek Test Script function is to streamline test operator’s complex measurement work by directly planning a set of changing voltage and

The uniqueness of GW Instek Test Script function is to streamline test operator’s complex measurement work by directly planning a set of changing voltage and current parameters via Microsoft Excel and uploading the edited Excel file to GW Instek power supplies so as to execute sequential power outputs. The following five test applications with different test patterns were easily executed by GW Instek Test Script function without software programming.       
 
Test Script allows users to run repetitive cycle tests by setting parameters including output voltage, current, time, cycle, OVP, OCP, Bleeder, etc. Four GW Instek power supplies support Test Script, including PFR, PSU, PSW, and PSB.     

Settings: Set and execute a pattern that switches 12V/1sec to 5V/1sec for 6 times with the current setting of 3A.

The output voltage rises from 0V to 5V in 50 seconds at the current setting of 10A and maintains the settings for 30 minutes and then the output is turned off automatically

* The above waveform is an ideal waveform. The actual waveform is limited by the voltage setting and bandwidth of the power supply models.

Burst signals are applied in the middle of the constant voltage output. For example, a continuous voltage output generates a burst noise that fluctuates between 12V and 8V. Each burst signal is 100ms and the burst signals last 1.5s that appears after every 10 minutes (600 s) of constant 12V output.

For durability tests such as lights, heaters, etc., the pattern that repeats for 18-hour output on and 6-hour output off for 100 days is as follows.

A test example of self-resetting PTC verifies its open circuit characteristic by increasing current from 0 to 3A with 16-step resolutions. 
Test Script can easily execute a series of different currents under a constant voltage setting to test the blown and reset characteristic of a self-resetting PTC.

To download Test Script and its setting procedures please go to http://www.gwinstek.com/en-global/Page/The_setting_of_Test_Script
Four GW Instek Power supplies support Test Script, including PFR, PSU, PSW, and PSB.

ຂ່າວທີ່ກ່ຽວຂ້ອງ

Triển lãm "Dây & Cáp điện 2026" - Ngày 2
25/11/y 14:31:19

Tại gian hàng D02, EMIN mang 4 thiết bị Rohde & Schwarz đến để trưng bày và vận hành trực tiếp: máy phân tích tín hiệu và phổ R&S®FSV3044, máy hiện sóng hiệu năng cao R&S®RTP134, máy phân tích mạng vector R&S®ZNLE4 và máy phân tích mạng vector cầm tay R&S®ZNH18

What Is 5 µs End-to-End Sync Verification in Substations?
25/11/y 10:55:08

In a 50 Hz digital substation using 80 Sampled Values per cycle, samples are 250 µs apart. End-to-end verification examines whether timing alignment is maintained so protection functions can use comparable measurements.

How Should Data Center Protection Relays Be Tested?
25/11/y 10:53:58

Data center relay testing should verify UPS transfer behavior, overcurrent pickup and reset, selectivity between switchgear levels, and generator protection outputs against approved settings.

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ