Test index: Moisture, ash ,volatile matter and LOI
Continuous test in batches: Yes
Standards: ISO 17246, ISO 18123/18122/18134, ISO 11722, ISO 1171,ASTM D3173/D3174/D3175/D7582, GB/T 30732, GB/T 212
Precision: 0.02% RSD
Furnace temperature: Room temperature~1000℃
Temperature control precision: ±2℃
Temperature resolution: 0.1℃
Reproducibility: Ash: 0.30% (<15.00%); 0.50% (15.00~30.00%); 0.70% (>30.00%)Volatile matter: 0.50% (<20.00%); 1.00% (20.00~40.00%); 1.50% (>40.00%)
Cooling time required for batches of test: No
Furnace Cooling (forced air/N2): 950 to 500°C<30 min
Balance Resolution: 0.0001g
Sample introduction and taking: Automatic
Max. Samples: 19 samples + 1 blank sample position
Quantity of sample / test time:: Full indexes for 19 samples< 120 min (Quick method)
Sample weight: 0.5 up to 5g
Max. power: 4kW
Interface:: RS232
Furnace Heating: Resistance Wound
Temperature Calibration: Standard thermocouple
Temp. control precision: ±2℃ (moisture) ±5℃ (ash, volatile matter)
Gas Flow Rate: GB:Moisture:Nitrogen,30~60 times/h Ash:Air 60~120 times/h ASTM:Moisture:Nitrogen or Air 2~4(Furnace Volume /min)volatile matter:Nitrogen 2~4(Furnace Volume /min)
Power requirement: AC 220 V(±10%),50 / 60Hz
Gas requirement: Nitrogen/Oxygen/Compressed Air
Gas Pressure: Air 5 to 6 bar (75 to 90 psi)
Minimum Gas Purity: Air/Nitrogen/Oxygen 99.5%; dry, oil-free
Sample weighing: Under normal temp.
Test Temperature: Moisture 105℃,Ash 815℃,Volatile matter 920℃~950℃ Can be customized
Humidity: <80%
Dimensions: 550x590x530mm
Weight: 70kg
Operational Control: Windows®-based software on external PC/Windows7/ WindowsXP
Advance Calculation: Yes
Analysis Report: Yes
Statistics Report: Yes
System Monitor: Yes
19 samples can be loaded once + 1 blank sample position for analyzing the moisture, ash and volatile matter.
Unique sample weighing mode, single sample or batch sample weighing are both available, makes the operation convenient.
Automatic temperature calibration function is available.
Flexible software design, test procedure, analysis time, temperature etc. can be customized.
LED displays on furnaces to show real-time balance weight data, it makes the sample weighing more convenient.
Single and dual furnace configurations available.