Display: 7 inch TFT Touch Screen (800×480)

Connectivity: USB×2; 10/100Mbit/s RJ-45×1

Memory: 2GB

Power Supply: Rechargeable Li-Ion Battery/AC Adapter

Battery Life: 10 hours continuous operation

Working Temp.: -20°C - 50°C

Storage Temp.: -40°C - 60°C

Humidity: 0 - 95% (Non-Condensing)

Weight: 2.1kg

Dimensions (L×W×H ): 290×175×75mm

OTDR Module: Wavelength

MTP-200-D100: 1528.77-1566.72nm @ 0.4nm Spacing

Dynamic Range(1): 38dB

Dead Zone(2): EDZ: 1m, ADZ: 4m

Selectable Range: SM: 1.3, 2.5, 5, 10, 20, 40, 80, 160, 240Km

Pulse Width: SM: 5ns,10ns, 30ns, 100ns, 300ns,1µs, 2.5µs,10µs, 20µs

Sampling Points: 256000

Averaging Time: Quick, 15s, 30s, 45s, 60s, 90s, 120s, 180s

Connector: FC/PC (Interchangeable SC, ST and LC )

Distance Accuracy: ±(1m + 5x10-5 x distance +sampling resolution)

Attenuation Accuracy: ±0.05 dB/dB

Reflection Accuracy: ±4 dB

Visible Laser Source: Output Power: ≥ -3dBm; MOD Frequency: 1Hz; Detecting Range: 5Km

Tunable Laser Source: 

Frequency Range: 191 - 196 THz

Wavelength Range: 1528-1566nm

Accuracy: 2.5 GHz

Line Width: 10 MHz

SMSR: 40 dB

Output Power Range: +9 dBm to +13 dBm (C Band)

Power Setting Resolution: 0.01 dB

Power Variation over Wavelength Range: ±0.5 dB

Minimum Channel Spacing: 50 GHz (0.4nm)

Reflection Accuracy: ±4 dB

Relative Intensity Noise: -140 dB/Hz


MCI100 Optical Connector Inspector Module (Optional): 

Field of View: 400µm×300µm

Resolution: ≤1.5µm

Focusing: Manual Focus

Microscope Dimensions: Ø32×175mm


PM100 Normal Power Meter Module (Optional): 

Calibrated Wavelength: 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm, 1650nm

Measurement Range: -70dBm - +6dBm (-60dBm - +6dBm @ 850nm)

Detector Type: InGaAs

Display Resolution: 0.01dB

Accuracy: ± 5% ± 0.01nW (±0.5dB@850nm)

*Specifications subject to change without notice.


Notes

(1)   Dynamic range measurement at 20µs pulse width and 180s averaging time;

(2)   Dead Zone measurement at 0.6Km and reflection <-45dB; EDZ measurement at 5ns, ADZ measurement at 10ns.


Order Information:

Standard Package

MTP-200, Lithium Battery, CD (User’s Manual and MTP Suite Software), Carrying Case, Warranty card, Calibration Certificate

Datasheet

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ