For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.LA
0
Product image

Pulsar measurement dBi3 Probifus Transducer (125 mm - 3 m (4.9 in - 9.8 ft))

ຕິດຕໍ່
ການຊຳລະເງິນທີ່ປອດໄພ
ການຮັບປະກັນຄຸນນະພາບ
ປ່ຽນ ແລະ ສົ່ງຄືນງ່າຍ
ມີບໍລິການຈັດສົ່ງ

Sensor Body Dimensions: 77 mm D x 134 mm H (3 in x 5.3 in)

Rear thread 1” BSP/NPT

Weight: 1 kg (2.2 lb)

Measurement range: 125 mm to 3 m (4.9 in to 9.8 ft)

Frequency: 125kHz

Beam Angle: <10°

Effective Beam Angle (using DATEM): 3°

Accuracy: 2 mm (0.08 in)

Resolution: 1 mm (0.04 in)

Housing Material: Valox 357 PBT (Polybutylene terephthalate)

Temperature Compensation: Automatic, internal temperature sensor, ± 0.5 °C/°F

Transducer Cable Requirements: Twin screened. Integral cable length 5 m, 10 m, 20 m or 30 m (16.4 ft, 32.8 ft, 65.6 ft, 98.4 ft)

Operating Temperature Range: 40 °C to +80 °C (-40 °F to +176 °F) process temperature

Ingress Protection: IP68 to BS EN 60068-2-17:1995 and BS EN 60529 (Nema 6P available)

Approvals: See EC Declaration of Conformity in the manual

Hazardous Area Approval: ATEX; Ex ia Zone 0 and FISCO

Power: Bus-powered, per IEC 61158-2; 20mA (general purpose or I.S. version) 20mA 18-24 V DC

Update Time: 1 to 2 seconds at 20mA current loop

Programming: PA modem; Simatic PDM, EDDL, FDT/DTM on request. PC interface 2-wire loop powered from PC or laptop. No external power is required.

Outputs: Profile 3.0.2, Class A with I&M functionality