EMC: In accordance to EN 61326
Upscale: 21 mA
Accuracy: Class A
RTD Type: 100 Ω Pt Sensor
Downscale: 3.6 mA
Span Note: 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
Span, Min: 50°C
Probe Length: 4 in
Body Material: Thermoplastic
Response Time: < 50 ms
Probe Diameter: 0.125 in
Supply Voltage: 8.5 to 32 Vdc
Factory Setting: 0 to 150°C/sensor break >21 mA (upscale)
Permissible Load: 700
Tmax. Electronic: 80°C
Electrical Output: 4 to 20 mA
Enclosure Ratings: IP67
Thermocouple Type: N/A
Supply Power Effects: Negligible
Electrical Connection: M12 4 pin Male
Permissible Load Note: 700 @ 24 Vdc [RLo= (Vsupply-8.5)/0.020]
electrical-connection: M12 4 pin Male
Enclosure Ratings Note: IP65 and IP67 in accordance to IEC60529
Relative Humidity, Max: 1
Relative Humidity, Min: 0%
Process Connection Size: N/A
Temperature Sensor Type: RTD
Process Temperature, Max: 500 °C
Process Temperature, Min: -50 °C
Range Configurations Note: It is possible set the input temperature range (span) by the M12TX-CONFIG-SETconfiguration kit (PC with OS Windows® required)
Operating Temperature, Max: 80 °C
Operating Temperature, Min: -40 °C
Temperature Influence Note: Maximum of ± 0.3°C/25°C (77°F) or ± 0.3% of span/25°C (77°F)
Temperature Influence, Max: ± 0.3%
Sensor Break Monitoring Note: Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
Zero Setting Adjustable Range: Any value between -50 to 50°C (-58 to 122°F)
Sensor Error Compensation Note: Over 2 points (maximum 1% of span)