Weight: 0 lb
Accuracy: ± 1 %
Materials: Aluminum, Polyethylene
Cable Length: 20 ft
Conductivity: > 20 µS/cm
Display Type: LCD
Accuracy Note: ± 1% of reading (between 10% and 100% of maximum flow) ± 3% of reading (between cutoff and 10% of maximum flow)
Output Detail: Current sinking pulse, Opto-isolated, 32 Vdc maximum at 10 mA maximum
Output Signal: DC Pulse
Pipe Size, Max: 3 in
Pipe Size, Min: 3 in
Supply Voltage: 10 to 30 Vdc
Number of Digits: 8
Enclosure Ratings: NEMA Type 4X
Materials, Wetted: 316 Stainless Steel, Glass, Polypropylene
Number of Outputs: 1
Supply Power Note: FMG800: 6 each “AA” alkaline cells (included), replaceable. Estimated life is 1 to 2 years depending on usage, FMG810: 10 to 30 Vdc @ 60 mA maximum (15 mA average), NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation.
Supply Power Type: DC
Media Compatibility: Acid Solutions, Conductive Liquids, Saltwater
Standard Pulse Rate: 1 unit/pulse out
Empty Pipe Detection: Hardware/software, conductivity-based
Battery Size and Type: Alkaline AA
Electrical Connection: M12 5 pin Male
Operating Pressure, Max: 150 psi
Process Connection Note: 1 NPTF, 2 or 3" flange clamps with 2 or 3 NPTF fitting kit
Process Connection Size: 3 in
Process Connection Type: NPT Female
Standard Pulse Rate Note: 1 unit/pulse out, Pulse width of 10 ms depending on unit selection
Storage Temperature, Max: 80 °C
Storage Temperature, Min: -40 °C
Volumetric Flow Rate, Max: 670 GPM
Volumetric Flow Rate, Min: 14 GPM
Operating Temperature, Max: 54 °C
Operating Temperature, Min: -12 °C