For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.LA
0

More Display. More Signals. More Usability.

17/07/y 09:31:22

Our award-winning 4 Series MSO sets a new standard for performance, analysis and overall user experience. It is built to handle more signals with greater resolution and added versatility.

Our award-winning 4 Series MSO sets a new standard for performance, analysis and overall user experience. It is built to handle more signals with greater resolution and added versatility.

Transform the 4 Series MSO into a powerful workhorse when performing advanced analysis in automotive, embedded serial design, logic analysis and power.

Automotive

  • View communications beyond processors at sensors, actuators and switches.

  • Decode and trigger on CAN, CAN FD, LIN, FlexRay, SENT or PSI5 traffic.

Embedded Serial Design


  • Enables automated decoding

  • Performs triggering on the most important signal event.

  • Search capability makes it easy to zero in on specific bus activity.


Logic Analysis

  • FlexChannel® Technology gives unrivaled channel flexibility

  • Each input can be configured as a single analog or eight digital channels, to work as a logic analyzer

Power

  • Speed up power supply troubleshooting, optimization and validation.

  • Perform power supply measurement such as Input/Output, Timing/Switching/ Magnetic analysis



For a limited time only, when you purchase a new 4 Series MSO, choose TWO FREE node locked options or get TWO FREE logic probes. Enjoy over 30% in savings today!

CHECK OUT FOR OFFER

ຂ່າວທີ່ກ່ຽວຂ້ອງ

Triển lãm "Dây & Cáp điện 2026" - Ngày 2
25/11/y 14:31:19

Tại gian hàng D02, EMIN mang 4 thiết bị Rohde & Schwarz đến để trưng bày và vận hành trực tiếp: máy phân tích tín hiệu và phổ R&S®FSV3044, máy hiện sóng hiệu năng cao R&S®RTP134, máy phân tích mạng vector R&S®ZNLE4 và máy phân tích mạng vector cầm tay R&S®ZNH18

What Is 5 µs End-to-End Sync Verification in Substations?
25/11/y 10:55:08

In a 50 Hz digital substation using 80 Sampled Values per cycle, samples are 250 µs apart. End-to-end verification examines whether timing alignment is maintained so protection functions can use comparable measurements.

How Should Data Center Protection Relays Be Tested?
25/11/y 10:53:58

Data center relay testing should verify UPS transfer behavior, overcurrent pickup and reset, selectivity between switchgear levels, and generator protection outputs against approved settings.

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ