Number of testing channels: 8~32 Route (every 8 routes as a group) (TCP-500X series can be expanded to 64 channels)
Screen size: 5-inch LCD touch screen
sensor type: S、R、B、N、K、E、J、T、W5/26、PT100、PT1000、Cu50 optional (requires TCP-500P、TCP-1000P)
Display basic accuracy: 0.2% + 0.5°C + 2 words (excluding thermocouple accuracy)
Display Function: (TCP-500XL has no curve display)Numerical/Curve Display/Column Display
DisplayCorrection: independent error for each channel linear correction F=kx+b (x=measured value)*Alarm
The alarm function: can be set with upper limit, upper limit, lower limit, and lower limit alarms, and also supports recording function
Alarm item: Customizable relay alarm output
Temperature unit: °C、K、°F
The system language: supports switching between Chinese and English interfaces
Test performance: 32 ARM microprocessor, screen response time<0.5S
Live test: Each channel is isolated from each other and resistant to high-frequency interference AC380V、DC500V (TCP-1000XH TCP-2000XH live test: AC1000V, DC1500V)
data protection: Data is not lost in case of power failure and can be stored for 72 hours to 180 days
Internal storage: built-in 8GB large capacity FLASH storage for data
Data export: supports external USB drive to export and store data (the instrument can also be connected to a USB cable to view data files)
Temperature unit: Display range Different range can be selected according to different sensors
Marking and commenting function: Each temperature value can be named arbitrarily with a custom name
Real Time Clock: Using hardware real-time clock with clock error of ±1 minute/year
sampling period: Three sampling speed options high 100ms/medium 500ms/low 1S
Record cycle: 0.1 second~9999 seconds/group (any set interval time)
Communication interface: comes standard with USB communication interface and data acquisition software (optional for RS-232/RS485), TCP-400B is not available
Communication protocol: PC and two types of Modbus
The power configuration: can operate normally within a wide voltage range of AC 85V~265V