AC Input: 220V±10%

Rating range:

Output voltage: 0-30V

Output current: 0-60A

Output power: 0-1800W


Load Regulation:

Voltage: ≤0.2%FS

Current: ≤0.2%FS


Set value resolution:

Voltage: 0.01V

Current: 0.01A


Readback value resolution:

Voltage: 0.01V

Current: 0.01A


Set value accuracy:

Voltage: ≤0.1%FS+20mV

Current: ≤0.3%FS+30mA


Readback value accuracy:

Voltage: ≤0.1%FS+20mV

Current: ≤0.3%FS+30mA


Ripple (20Hz-20MHz):

Vpp: ≤1%FS+100mV

Vrms: ≤0.3%FS+50mV


Dynamic response time (10%-90% load): ≤5ms

Voltage settings and presets: Rotary encoder

Current settings and presets: Rotary encoder

Interface: Standard RS232, RS485, LAN

Protective function: With overvoltage protection, overcurrent protection, short circuit protection, temperature protection

Cooling method: Forced air cooling

Operating environment: Indoor use design, temperature: 0℃~40℃; humidity: 10%~85% RH

Storage environment: Temperature: -20℃~70℃; humidity: 10%~90% RH

Dimensions (WxHxD): 218×44×435mm

Weight: About 4kg

Brief Introduction 

JINKO JK-P series is a high-performance DC power source independently developed and produced by jinko factory for scientific research and industrial applications. This series of products have simple operation, small size, high efficiency, high precision, high stability and other performance, with perfect protection function, allowing users to use the product more assured, more stable and more reliable. 

Features: 

1. Standard 1U, 2U, 3U size, easy to use on the rack;

2. Standard power 1800W-15000W;

3. Support parallel power expansion function, the parallel power can reach 120KW;

4. Voltage and current display, the working status is clear at a glance;

5. Automatic switching of CV/CC working mode;

6. Standard RS232, RS485, LAN port, optional CAN;

7. It has the function of remote compensation to compensate the voltage drop on the line;

8. Various protection functions of overvoltage, overcurrent and short circuit;

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ