For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.LA
0
Product image

HT SOLAR IVe IV curve tracer ເຖິງ 15A ຫຼື 1500VDC ແລະເຄື່ອງຕັດໄມ້ປະສິດທິພາບ PV (15A, 1500VDC)

ModelSOLAR IVe
ຕົ້ນກຳເນີດItaly
ການຮັບປະກັນ12 ເດືອນ
ຕິດຕໍ່
ການຊຳລະເງິນທີ່ປອດໄພ
ການຮັບປະກັນຄຸນນະພາບ
ປ່ຽນ ແລະ ສົ່ງຄືນງ່າຍ
ມີບໍລິການຈັດສົ່ງ

1. CERTIFIER OF SINGLE PHASE PV INSTALLATION

DC Voltage: 15.0 ÷ 1499.9V; ± (0.5%rdg + 2dgt)

AC TRMS Voltage: 50.0 ÷ 265.0 V; ± (0.5%rdg + 2dgt)

DC current (by external transducer clamp):

-1100 ÷ -5/ 5 ÷ 1100; ± (0.5%rdg + 0.6mV)

AC TRMS Current (by external transducer clamp): 1 ÷ 1200; 47.5 ÷ 63.0; ± (0.5%rdg + 0.6mV)

1< FS ≤ 10: 0.05; 0.01

10< FS ≤ 100: 0.5; 0.1

100< FS ≤ 1000: 5A; 1

DC Power (Vmeas > 150V):

1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS)

10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS)

100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS)

AC Single phase power (@ PF = 1, Vmeas > 200V):

1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS)

10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS)

100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS)

Frequency: 47.5 ÷ 63.0Hz; ±(0.2%rdg+1dgt)

Irradiance (by reference cell) : 1 ÷ 65.0; ±(1.0%rdg + 5dgt)

Temperature (by external probe PT1000): -20.0 ÷ 100.0; ± (1.0%rdg +1°C)

2. I-V CURVE and IVCK MEASUREMENTS

I-V, IVCK: VDC Voltage @ OPC: 15.0 ÷1499.9; ± (0.5%rdg + 2dgt)

I-V, IVCK: IDC Current @ OPC: 0.10 ÷ 15.00; ± (1.0%rdg + 2dgt)

I-V: DC Power @ OPC (Vmpp >30V, Impp >2A): 50 ÷ 99999; ± (1.0%rdg + 6dgt)

I-V, IVCK: VDC Voltage (@ STC): 5.0 ÷ 999.9; ± (4.0%rdg + 2dgt)

I-V: IDC Current (@ STC): 0.10 ÷ 99.00; ± (4.0%rdg + 2dgt)

I-V: DC Power @ STC (Vmpp >30V, Impp >2A): 50 ÷ 99999; ± (5.0%rdg + 1dgt)

Irradiance (with reference cell): 1.0 ÷ 100.0; ÷(1.0%rdg+5dgt)

Temperature of module (with auxiliary PT1000 probe): -20.0 ÷ 100.0; ÷(1.0%rdg+1°C)


Accessories provided:

User manual on CD-ROM and quick guide

ISO9000 calibration certificate

SP-0500

Standard Clamp HT4004

Standard Clamp HT4005K

Reference Cell HT304N

M304

Remote Unit SOLAR02

Probe PT300N

Case VA500

Set of Adapter KITPVMC4

Set of Adapter KITPVMC3

Multi- Language Software TOPVIEW2006


 
 

Datasheet_VN


Manual_VN


Datasheet_EN


Manual_EN


Brochure_EN


 
 

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ