INSTRUMENT SPECIFICATIONS

Size: 10” L x 3.0” W x 2.5” H (25.5 cm x 7.6 cm x 6.4 cm)

Weight: 26 oz (738 g)

Sensors: Photoionization sensor with standard 10.6 eV or optional 9.8 eV or 11.7 eV lamp

Battery

• Rechargeable, external field-replaceable Lithium-Ion battery pack

• Alkaline battery adapter

Running time: 16 hours of operation (12 hours with alkaline battery adapter)

Display Graphic: 4 lines, 28 x 43 mm, with LED backlight for enhanced display readability

Keypad: 1 operation and 2 programming keys, 1 flashlight on/off

Direct Readout

Instantaneous reading

• VOCs as ppm by volume (mg/m³)

• High values

• STEL and TWA

• Battery and shutdown voltage

• Date, time, temperature

Alarms: 95dB at 12” (30 cm) buzzer and flashing red LED to indicate exceeded preset limits

• High: 3 beeps and flashes per second

• Low: 2 beeps and flashes per second

• STEL and TWA: 1 beep and flash per second

• Alarms latching with manual override or automatic reset

• Additional diagnostic alarm and display message for low battery and pump stall

EMC/RFI:

Compliant with EMC directive (2004/108/EC)

EMI and ESD test: 100MHz to 1GHz 30V/m, no alarm

Contact: ±4kV

Air: ±8kV, no alarm

IP Rating

• IP-67 unit off and without flexible probe

• IP-65 unit running

Datalogging: Standard 6 months at one-minute intervals

Calibration:

Two-point or three-point calibration for zero and span.

Reflex PID Technology™

Calibration memory for 8 calibration gases, alarm limits, span values and calibrationdates

Sampling Pump:

• Internal, integrated flow rate at 500 cc/mn

• Sample from 100’ (30m) horizontally or vertically

Low Flow Alarm: Auto pump shutoff at low-flow condition

Communication & Data Download

• Download data and upload instrument set-up from PC through charging cradle or using BLE module and dedicated APP

• Wireless data transmission through built-in RF modem

Wireless Network: Mesh RAE Systems Dedicated Wireless Network

Wireless Range (Typical)

Up to 15ft (5m) for BLE

EchoView Host: LOS > 660 ft (200 m)

ProRAE Guardian & RAEMesh Reader: LOS > 660 ft (200 m)

ProRAE Guardian & RAELink3 Mesh: LOS > 330 ft (100 m)

Temperature: -4° to 122° F (-20° to 50° C)

Humidity: 0% to 95% relative humidity (non-condensing)

Attachments: Durable bright yellow rubber boot

ENSOR SPECIFICATIONS

VOCs:

Range: 

0 to 999.9 ppm

1,000 to 15,000 ppm

Resolution: 

0.1 ppm

1 ppm

Response Time T90

< 3 s

< 3 s

Datasheet

ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ