-Measurement range: 0.5% to 100% with 0.01% measurement value resolution
-Dynamic range: 200 (dark signal measurement 0.5% with -8° and a very low scattering mirror at the measurement port
-Typical Measurement uncertainty: ± 0.5% incl. the uncertainty of the calibration standards
-Repeatability: ± 0.1*[1-log10rg]%; rg = regular/hemispherical
-BN-R98-D2C-PP: ± 0.6% (k=2), diffuse reflection (ODM98)
-Integrating sphere: 500mm diameter with barium sulfate coating (ODP97)
-Measurement port: 50mm diameter with knife-edge
-Self absorption correction port: 50mm diameter with knife-edge. 90° position for the measurement port
-Sample holder: With pull springs. Shadowing of the measurement port from ambient light. Attachment of the calibration standard
-Detector port:
-8° port:25mm diameter. 8° alignment to the measurement port. Slide&Fix holder for fast exchange of port plugs (reflectance measurement) and light traps with 10mm aperture (scattered transmission measurement)
-Detector port: +8° port: 50mm diameter. 8° alignment to the measurement port
-Sensor: Photometric detector head with 1cm² light-sensitive surface
-f1' (spectral mismatch): f1’ uncertainty <6% (DIN 5052 T7 class B)
-Measurement signal: approx. 20.3nA with BN-R98-D2 reflection standard. 8° port with port plug
-Light Source: Radiation bundle with -8° direct alignment to the center of the measurement port and alignment of the reflection rays –8° port
-Temperature range: 2856K +/-20K (Standard illuminant A)
-Light Source: LH-100-UV, 100W/12V quartz halogen lamp
-Cooling: Cooling of the lamp holder through active air circulation using a fan
-Connector: Laboratory cables with banana plugs
-Light Guide: Approximate 18mm diameter on the sample and approx. 9mm on the –8° port
-Warm-up time: Approximate 10min
-Design:
Similar to the X1-RM optometer. ISM-50-R-V01 Firmware.
Calibration, substitution correction, measurement of the transmission degree, measurement of the scattered light proportion, calculation of the directed light proportion, display in %
Remote control of the lamp power supply unit
-Display:
LCD graphic display 97x32 pixel
Active size 14.3mm x 35.8mm
LED backlight can be switched on/off
Text display 4 rows, 14 characters per row
-Operation buttons on the front control panel: Three
-Temperature range:
Operation: 5 to 40°C
Storage: -10 to 50° C
-Lamp power supply: Similar design to the LPS-100-RM.
-Output power: 100W / 0 - 10A / max. 13.5V
-Resolution: 0.2mA
-Temperature range: +-0.3mA/°K
-Stability: +-1mA over 8 hours, 60 min after switch on in a constant environment
-Interface: RS232 / RS485: 19200 Bd, 8D, 1S, N
-Temperature range:
Operation: 10 - 30°C (with free air circulation)
Storage: 5 - 50°C
-Power Supply: 120 to 230 VAC, 50 to 60Hz
-Dimensions: 3/4 19” broad bench-top housing similar to the BTH-19-3-4