AC voltage measurement

Range500 V

Resolution0.1 V

Accuracy 45 Hz – 66 Hz0.8% + 3

Input impedance360 kΩ

Overload protection660 V rms

Continuity testing (RLO)

Range (autoranging)20 Ω / 200 Ω / 2000 Ω

Resolution0.01 Ω / 0.1 Ω / 1 Ω

Open Circuit Voltage>4 V


Insulation resistance measurement (RISO)

Accuracy of test voltage (at rated test current)+10%, -0%

Test voltage100 V

250 V

500 V

1000 V

Insulation resistance range20 MΩ / 50 MΩ

20 MΩ / 100 MΩ

20 MΩ / 200 MΩ

20 MΩ / 200 MΩ / 500 MΩ

20 MΩ / 200 MΩ / 1000 MΩ

Resolution0.01 MΩ / 0.1 MΩ

0.01 MΩ / 0.1 MΩ

0.01 MΩ / 0.1 MΩ

0.01 MΩ / 0.1 MΩ / 1 MΩ

0.01 MΩ / 0.1 MΩ / 1 MΩ

Test current1 mA @ 50 kΩ

1 mA @ 100 kΩ

1 mA @ 250 kΩ

1 mA @ 500 kΩ

1 mA @ 1 MΩ


Loop and line impedance (ZI)

Range10 Ω / 0.001 Ω / High current mΩ mode

Resolution0.01 Ω / 0.1 Ω / 1 Ω


Prospective earth fault current, PSC test

Range1000 A / 10 kA (50 kA)

Resolution1 A / 0.1 kA

ComputationProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.


RCD testing, RCD types tested

RCD TypeA4, AC¹, G², S³

Notes¹Responds to AC

²General, no delay

³Time delay

4Responds to pulsed signal

5Responds to smooth DC signal


Tripping speed test (ΔT)

Current settings¹10-30-100-300-500-1000 mA – VAR; 10-30-100 mA

Multiplierx ½, x 1; x 5

Measurement rangeRCD

Type G:310 ms; 50 ms

RCD Type S:510 ms; 160 ms

Notes

¹1000 mA type AC only

700 mA maximum type A in VAR mode

VAR mode not available for type B.


RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)

Current range:30% to 110% of RCD rated current¹

Step size:10% of IΔN²

Dwell time:Type G300 ms/step

Type S:500 ms/step

Measurement accuracy±5%

Specified trip current ranges (EN 61008-1)

50% to 100% for Type AC

35% to 140% for Type A (>10 mA)

35% to 200% for Type A (≤10 mA)

50% to 200% for Type B

²5% for Type B

Notes¹30% to 150% for Type A IΔN > 10 mA

30% to 210% for Type A IΔN = 10 mA

20% to 210% for Type B


General Specifications

Size (L x W x H)10 x 25 x 12.5 cm

Weight (incl. batteries)1.3 (kg)

Battery size, quantityType AA, 6 ea.

SealingIP-40

SafetyComplies with EN/IEC 61010-1 and EN/IEC 61010-2-034

OvervoltageCAT III / 500V; CAT IV 300V

PerformanceEN61557-1 to EN61557-7 and EN61557-10


Includes:

6x AA (IEC LR6) cell batteries

C1600 hard carrying case

Zero adapter

Heavy duty mains cord

STD standard test lead set

Padded carrying and waist strap

Quick reference guide

TP165X remote control probe and lead