Includes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 62 Max+ Infrared Thermometer

With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease

Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit

The Fluke 62 MAX+ Infrared Thermometer measure -30 °C to 650 °C (-22 °F to 1202 °F), is extremely accurate, and has an IP54 rating for water resistance and dust proof

The Fluke 1587 FC 2-in-1 Insulation DMM

Pl/DAR measurements with TrendIt™ graphs

Memory storage through Fluke Connect Measurements app

Temperature Compensation through Fluke Connect Measurements app

VFD low-pass filter for accurate motor drive measurements

Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V

Insulation test voltages 500 V, 1000 V

Insulation test: 0.01 MΩ to 2.0 GΩ

Insulation test: 0.1 MΩ to 600 MΩ

Auto-discharge of capacitive voltage

Insulation test smoothing reading

Frequency / Capacitance / Diode test / Temperature

Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps

Resistance (0.1Ω  to 50 MΩ) / Continuity / Auto power off

Remote probe, test leads, alligator clips, K-type thermocouple, hard case

Fluke i400 AC Current Clamp

Use with your Fluke 1587 FC to measure 1A AC to 400 A AC

1 mA/Amp output guarantees easy reading CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection

Specially designed to offer maximum utility in a very compact shape

Maximum conductor: Ø 32 mm

Fluke 62 MAX+ Infrared Thermometer

Temperature range -30 °C to 650 °C (-22 °F to 1202 °F)

Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater

-10 °C to 0 °C: ±2.0

-30 °C to -10 °C: ±3.0

Response time (95%) Fluke 62 MAX+ < 300 ms (95% of reading)

Spectral response 8 to 14 microns

Emissivity 0.10 to 1.00

Optical resolution 12:1 (calculated at 90% energy)

Display resolution 0.1 °C (0.2 °F)

Repeatability of readings ±0.5%

Reading or < ±0.5 °C (1 °F), whichever is greater

Power AA battery

Battery life 8 hours with laser and backlight on


ຕິດຕາມຂ່າວສານ ແລະ ຂໍ້ສະເໜີ

ຮັບສ່ວນຫຼຸດພິເສດຕາມປະລິມານ, ອັບເດດລາຄາຂາຍສົ່ງ ແລະ ການແຈ້ງເຕືອນສິນຄ້າໃໝ່ສົ່ງກົງເຖິງອິນບັອກຂອງທ່ານ.

ໂດຍການສະໝັກສະມາຊິກ, ທ່ານຍອມຮັບ ເງື່ອນໄຂການໃຫ້ບໍລິການ ແລະ ນະໂຍບາຍຄວາມເປັນສ່ວນຕົວ ຂອງພວກເຮົາ.

ການຊ່ວຍເຫຼືໍາດ່ວນ

ເຂົ້າເຖິງຜູ້ຊ່ຽວຊານທີ່ໄດ້ຮັບການຢັ້ງຢືນຂອງພວກເຮົາໂດຍກົງ