115 VAC, 50/60 Hz

Temperature Control Method: Direct Heat and Air Jacket using Microcontroller PI

Ambient Temperature Range: 18 to 32˚C (64 to 89.6˚F)

Temperature Range, °C: Ambient +5 to 60

Temperature Uniformity, °C*: < ±0.5

Temperature Accuracy, °C*: < ±0.1

Temperature Recovery Time** (after 30 seconds door opening, 98% from initial value): ≤6 minutes

CO2 Control System: Microcontroller PI

CO2 Range, % CO2: 0-19.5

CO2 Accuracy, % CO2***: ±0.1

CO2 Sensor: Infrared (IR) Sensor

CO2 Recovery Time**** (after 30 seconds door opening, 98% from initial value): ≤6 minutes

Humidity

Humidification Method: Humidity pan

Humidity Range, %RH (at 37ºC)*****: 85-90

Physical Construction

Interior Volume: 240L

External Dimensions (W x D x H): 750 x 770 x 900 mm

Internal Dimensions (W x D x H): 595 x 640 x 633 mm

Chamber Construction

Main Body: Electrogalvanized steel with Isocide™ antimicrobial coating

Interior Material: Stainless steel, type 304

Number of Shelves: 3

Maximum Number of Shelves: 7

Electrical Configuration: 110-130 VAC, 50/60 Hz

Full Load Amps: 13.4 A

Electrical Configuration: 220-240 VAC, 50/60 Hz

Full Load Amps: 6.5 A

Net Weight: 121 kg

All data recorded is specified for standard models with unloaded chambers and tested under optimum factory setting conditions of 23°C and 60% ambient humidity.

Contamination Control Methods

1) Main body is electro-galvanized steel with Isocide™ antimicrobial coating;

2) 90˚C moist heat OVERNIGHT decontamination cycle (HPA validated);

3) ULPA filter******

4) 0.2-micron inlet filter for gas inputs;

5) 1-micron air circulation filter

6) UV Lamp (for CLM-UV models only)

*Results are achieved when tested at 37°C as set point. Results may vary if set point changes and calibration is needed.

**For temperature not exceeding 37.2°C.

***Results are achieved when tested at 5% CO2 as set point. Results may vary if set point changes and calibration is needed.

****For CO2 level not exceeding 5.2%.

***** Esco does not guarantee condensation-free chamber at humidity level higher than 90%.

******Not available for 50 L models.