- Measurements:

+ Oxygen (O2):

Range: 0-21% vol

Accuracy: ± 0.2% vol

Resolution: 0.1% vol

+ Carbon Monoxide (CO):

Range: 0-10,000 ppm

Accuracy: ± 2%

Resolution: 1.0 ppm

+ Nitric Oxide (NO):

Range: 0-5000 ppm

Accuracy: ± 5%

Resolution: 1.0 ppm

+ Nitrogen Dioxide (NO2):

Range: 0-1000 ppm

Accuracy: ± 5%

Resolution: 1.0 ppm

+ Sulfur Dioxide (SO2):

Range: 0-5000 ppm

Accuracy: ± 5%

Resolution: 1.0 ppm

+ Combustibles (CxHy):

Range: 0-4.00% vol

Resolution: 0.01% vol

+ Methane (CH4):

Range: 0-5% vol

Accuracy: ± 5%

Resolution: 0.01% vol

+ Carbon Dioxide (CO2):

Range: 0-20%

Accuracy: ± 5%

Resolution: 0.1% vol

+ Draft / Pressure:

Range: ±40” H2O

Accuracy: ± 2%

Resolution: 0.004” H2O

+ Gas Temperature:

Range: 32-1832° F**

Accuracy: ± 0.5%

+ Ambient Temperature:

Range: 40-122° F

Accuracy: ± 1° F

+ O2 Correction:

Range: 0-20% O2

+ Carbon dioxide:

Range: 0-CO2 max of fuel

- Dimension: 22” x 15” x 7.5”

- Weight: 18.75 lbs