INPUT
Input Phase: Single-Phase
Rated input current (Maximum Load): 14.97A
Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type: C20 inlet
OUTPUT
Output Capacity (VA): 3000
Output Capacity (kVA): 3
Output Capacity (Watts): 2700
Output Capacity (kW): 2.7
Power Factor: 0.9
Crest Factor: 3:1
Nominal Voltage Details: Nominal output voltage is user configured on first power-on
Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details: Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation
Output Voltage Regulation (Line Mode): +/- 2%
Output Voltage Regulation (Economy Line Mode): +/- 10%
Output Voltage Regulation (Battery Mode): +/- 2%
Included Output Power Cables: Includes 2 C13 to C14 and 1 C19 to C20 power cables
Load Management Receptacles: Two switchable 4 outlet load banks (3 C13 and 1 C19 per bank)
Output AC Waveform (AC Mode): Pure Sine wave
Output AC Waveform (Battery Mode): Pure Sine wave
Nominal Output Voltage(s) Supported: 200V; 208V; 220V; 230V; 240V
Output Receptacles: C13; C19
Individually Controllable Load Banks: Yes
BATTERY
Battery Type: Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.): 5 min. (2700W)
Runtime Half Load (min.): 13.5 min. (1350W)
Expandable Runtime: Yes
External Battery Pack Compatibility: BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)
DC System Voltage (VDC): 72
Battery Recharge Rate (Included Batteries): 3.0 hours from 10% to 90% (typical, full load discharge)
Battery Access: Front panel battery access door
Internal UPS Replacement Battery Cartridge: RBC72S
Battery Replacement Description: Hot-swappable, replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description: Online, double-conversion power conditioning
Overvoltage Correction: 2% output voltage regulation during overvoltages to 288
Undervoltage Correction: 2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
USER INTERFACE, ALERTS & CONTROLS
Switches: 5 front panel switches: On/Off, Up, Down and Escape
Alarm Cancel Operation: Power-fail alarm can be silenced by following on-screen prompts
Audible Alarm: Audible alarm indicates power failure, low battery, overload and fault
LED Indicators: 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)