Standard test methods: ASTM D86 (Group 0, 1, 2, 3, 4), ASTM D850, ASTM D1078, EN ISO 3405 (Group 0, 1, 2, 3, 4), IP 123, IP 195, JIS K 2254, GOST 2177, ASTM D524, ASTM D4530

Operation

User interface: 10" TFT color touchscreen, solvent-proof

Heating system: 

Low mass/low voltage heating system with automatic positioning of heater and safety shield

Automatic initial heater settings and heater regulation

Cooling fan to quickly reach safe handling temperature after test

Condenser system:

Liquid-free cooling with Peltier technology

Temperature range: 0 °C to 80 °C, resolution: 0.1 °C

Receiving chamber:

Liquid-free cooling with Peltier technology

Temperature range: 0 °C to 80 °C, resolution: 0.1 °C

Corrosion-proof:

Automated reduced VOC emission

Vapor temperature: Pt100, class A (metal or glass)

Temperature range: 0 °C to 450 °C, resolution: 0.1 °C

Integrated calibration memory with 20 calibration points and automatic read-out (ID detection)

Automatic correction by barometric pressure

Sample volume: Optical static detection system with contact image sensor (CIS) technology

Sample volume scan before test start to measure initial volume (converted to 100 %, if necessary)

Residue scan in receiving chamber with automatic calculation of loss

Volume range: 0 mL to 103.5 mL, resolution: 0.01 mL

Accuracy: ±0.1 mL

Ambient pressure: Built-in pressure sensor, range: 30 kPa to 110 kPa, resolution: 0.1 kPa

Ambient humidity: Built-in humidity sensor, range: 0 % to 95 % (rel. humidity)

Ambient temperature: Built-in temperature sensor, temperature range: -20 °C to +80 °C, resolution: 0.1 °C

Status light: Yes

Test results: >4000

User defined test methods: >200

Safety

Fire extinguisher:

Built-in fire extinguisher with IR sensor for fire detection

Connection of 4 bar to 6 bar CO2 or N2

Condition monitoring system: Detection of flask size, flask support board, vapor temperature sensor, heater shield, heater lift, condenser cleaning, receiving chamber door, receiving cylinder, drip plate, detection if fire extinguishing gas is connected

Operating Requirements

Temperature: 10 °C to 35 °C

Relative humidity: 10 % to 80 % relative humidity at 35 °C

Voltage: 100 V to 240 V, 50/60 Hz

Total power: 900 W

Altitude: 0 m to 5000 m

Dimensions and Weight

Dimensions:  approx. 406 mm × 525 mm × 645 mm (W × D × H)

Weight: approx. 40 kg

Further Features

Connectivity: 1 × Ethernet, 4 × USB, Bluetooth, Wi-Fi, AP Connect, LIMS

Accessories: Dry point sensor, 200 mL flask, bar code reader, printer, receipt printer, keyboard, various certified reference materials (CRM)