Voltage Test Range: 10~100V
Voltage Accuracy: ± (0.2% of reading + 0.2% of range)
Charge Current: 200~20000mA
Discharge Current: 200~40000mA
Current Accuracy: ± (0.2% of reading + 0.2% of range)
CV Cut-off Current: Min 50mA
Capacity Accuracy: ±1‰
Discharge Power: ≤4000W
Patrol Time: Actual time <2S
Timing Range: 0~999 h/work step
Data Logging Interval: ≥5S
Communication Box Version: 1.1 series
Charge Mode: CCCV charge
Charge Cut-off Condition: Voltage, current, relative time, overcharge protection
Discharge Mode: CC discharge
Discharge Cut-off Condition: Voltage, relative time, overdischarge protection
Cycle Measurement Range: 1~999 times
Number of Work Steps in a Single Cycle: 100
Equipment Function
Charging and discharging function: with constant current and voltage charging function, constant current discharging function, charging and discharging of the battery, recording the battery capacity.
Charging and discharging interface: fully meet the requirements of battery pack charging and discharging with the same port and charging and discharging sub-port, i.e. 2 wires (P+ P-), 3 wires (P+ P- C-) and positive plate charging protection, negative pole charging protection. 3 wires (P+ P- C-) and positive plate charge protection, negative plate discharge protection of power tool batteries (CH+ P+ P-).
Checking voltage protection:detecting whether the battery charge protection and discharge protection are working by charging and discharging the battery.
Safety protection:anti-reverse connection protection function, power-down data protection, support continuous measurement, voltage upper and lower limit setting protection, and
safe discharge current protection.
Online mode: the instrument can be connected to PC through serial port for single unit or less than 5 units; for more than 5 units, a network connection mode is adopted and a network port is provided at the PC side to control up to 30 units.
Control system: The software system adopts the classical and mature C/S mode, with two modes of communication: serial port can achieve accurate communication of several instruments in short distance, and network can achieve accurate communication of multiple instruments in long distance