Number of Cabinet Channels: 18 channels
Channel Action Mode: Completely independent
Main Channel Operating Mode: Charging: constant current CC, constant current constant voltage charging CCCV; Discharge: constant current discharge CD, constant power CP; Standing and stopping.
Main Channel Test Stop Conditions: Time, voltage, current, capacity, etc.
Charging Voltage Range: 5V ~ 30V
Discharge Voltage Range: 5V ~ 30V
Voltage Accuracy: ±(0.1%RD+0.1%FS)
Voltage Resolution: 1mV
Maximum Output Current: Charge current 20A, discharge current 20A
Minimum Output Current: 100mA
Current Accuracy: ±(0.1%RD+0.1%FS)
Current Resolution: 1mA
Output Power: Single channel continuous operation maximum power 600W
Auxiliary Channel Parameter Cutoff Function: The main channel step can be set to stop or switch when the auxiliary channel signal reaches a certain condition.
Control Procedure: Support data protection due to power failure, manual stop and continued testing from data files.
Safety Protection Conditions: Lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend.
Auxiliary Channel Protection Conditions: Upper voltage limit, lower voltage limit, upper temperature limit, lower temperature limit.
Number of Cycles: Maximum 9999
Step Time Unit: Support h, min, s format
Data Upload Interval: Minimum 5S
Cycle List: Cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc.
Process List: Process serial number, working mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc.
Detail List: Record serial numbers, system time, cumulative time, voltage, current, energy, power, etc.
Data Export Method: The data can be exported into EXCEL and chart files, supporting various data analysis curves such as charge/discharge efficiency, charge/discharge curves, voltage, capacity, current-time characteristics, etc.
Advantages
1.Equipment accuracy (0.1%RD +0.1%FS), high stability;
2.Independent charging and discharging conditions can be set after free grouping for each channel;
3.Complete input and output, software and hardware protection, reverse connection protection, power-off connection protection and other functions;
4.Channel start without impact current, constant current to constant voltage seamless transition, without any current surge;
5.Network integrated management, a computer centralized control, support remote monitoring;
6.Modular design concept, box plug-in design, easy to maintain;
7.Clear and comprehensive data, real-time monitoring and uploading MES system;
8.The cabinet can be extended.