For full functionality of this site it is necessary to enable JavaScript.

FLUKE FLUKE-1535/APAC Insulation Resistance Meter (FLUKE-1535, 2500V, 500GΩ)

  • Manufacturer:FLUKE
    Model: FLUKE-1535/APAC
    P/N: 5304189
    Origin: China
  • Contact
    • Request a Quotation

Up to 500 GΩ insulation resistance measurement range

Fast-measurement design, faster & stable resistance reading, higher efficiency

Automatic calculation of polarization index (PI) and dielectric absorption ratio (DAR)

Low power design meets the requirements of high-intensity work: up to 1300 times of 2500 V measurement, and up to 6500 times of 250 V measurements*

High-safety design with dangerous voltage alarm function, and complies with CAT IV 600V standard and China power industry specifications DLT845

The new high-reliability design, all specifications are met even under the environment of 50 °C temperature and 80% RH; all probes and corresponding ports are tested for 30,000 mating test

Details

Datasheet

Product overview: Fluke 1535 and 1537 Insulation Resistance Tester and Megohmmeters

Fast, accurate, reliable insulation testing in a portable lightweight package

The Fluke 1535 and 1537 2,500 V Insulation Resistance Testers are engineered to simplify frontline troubleshooting whether you’re on the factory floor or working in the field at a solar installation. With user selectable test voltages from 250 V to 2,500 V and resistance measurements up to 500 GΩ these testers allow you to cover more workload with a single tool. Equipped with an intuitive user interface, a short circuit current of up to 5 mA and a CAT IV 600 V rating these portable high-voltage insulation testers can deliver rapid and stable resistance measurements no matter where you take them. The 1537 Insulation Resistance Tester also allows you to store measurements for later review or PC transfer, using the provided software.

  • Selectable Voltage Tests:

     Tailor your tests with user-selectable voltages of 250 V, 500 V, 1000 V, and 2500 V to cover both industrial and solar applications.

  • Extended Insulation Resistance Measurement:

     Reach up to 500 GΩ in insulation resistance measurement for a thorough analysis.

  • Intelligent Calculations:

     Automatically calculate Polarization Index (PI) and Dielectric Absorption Ratio (DAR), minimizing the influence of environmental factors.

  • High Measurement Capacity:

     Execute up to 1,300 measurements at 2,500 V or 6,500 measurements at 250 V on a single charge, enhancing productivity.

  • Enhanced Safety Features:

     Benefit from a CAT IV 600V rating and a built-in voltage alarm function for heightened safety during operations.

The Fluke 1537 has these additional features:

  • Extended Measurements:

     The Fluke 1537 enhances your testing capabilities with AC/DC voltage and resistance measurements.

  • Stable Resistance Measurements:

     Achieve faster, more stable insulation resistance measurements with a short circuit current up to 5mA.

  • Fine-tunable Test Voltage:

     Adjust the test voltage from 250 V to 2500 V in 100 V increments to meet specific testing requirements.

  • Dielectric Discharge Rate Calculation:

     Automatically calculate the dielectric discharge rate (DD) to aid in identifying elusive insulation issues.

  • Ramp Test Mode:

     Linearly increase the applied test voltage 100 V/s to help identify potentially hard to identify fault conditions.

  • Visual and Audio Continuity Indicator:

     Verify continuity visually on the screen display or with the audible indicator so you can focus on your testing procedure without looking at the display.

  • Customizable Testing Parameters:

     Set user-defined labels, adjust test duration, and store measurement results for a tailored testing experience.

  • Effortless Data Management:

     Download and manage data effortlessly with the provided PC software.

Specifications: Fluke 1535 and 1537 Insulation Resistance Tester and Megohmmeters

General Specifications

Display

73.5 mm x 104 mm

Battery

8 AA alkaline cells, IEC LR6

Dimensions (H x W x L)

184 mm x 211 mm x 93 mm

Weight

1.3 kg

Temperature

Operating temperature

-10 °C to +50 °C

Storage temperature

-20 °C to +60 °C

Operating humidity

Non-condensing (<10 °C)

≤80 % RH (10 °C to 30 °C)

≤50 % RH (30 °C to 50 °C)

Altitude

Operating altitude

2000 m

Storage altitude

12000 m

Overvoltage category

CAT IV 600 V

Safety

General

IEC 61010-1, Pollution Degree 2

IEC 61557-1

Measurement

IEC 61010-2-030: CAT IV 600 V

IEC 61010-2-034: 2500 V dc

Insulation resistance measurement

IEC 61557-1, IEC 61557-2

IP Rating

IEC 60529 IP40

Electromagnetic Compatibility (EMC)

International

IEC 61326-1: Electromagnetic environment for portable equipments

IEC 61326-2-2 CISPR 11: Group 1, Class A

Electrical Specifications

The meter's accuracy is specified for one year after calibration at operating temperatures of 10°C to 30°C. For operating temperatures outside the range (-10°C to +10°C and +30°C to +50°C), add ± 0.25% per °C, except on the 20% bands, add ± 1% per °C.

Insulation resistance testing

Test voltage

Range

Resolution

Accuracy

250 V

<200 kΩ

Unspecified

Unspecified

200 kΩ to 500 kΩ

1 kΩ

5 %

0.50 MΩ to 5.00 MΩ

.01 MΩ

5 %

5.0 MΩ to 50.0 MΩ

0.1 MΩ

5 %

50 MΩ to 500 MΩ

1 MΩ

5 %

0.50 GΩ to 5.00 GΩ

0.01 GΩ

5 %

5.0 GΩ to 50.0 GΩ

0.1 GΩ

20 %

>50 GΩ

Unspecified

Unspecified

500 V

<200 kΩ

Unspecified

Unspecified

200 kΩ to 500 kΩ

1 kΩ

5 %

0.50 MΩ to 5.00 MΩ

.01 MΩ

5 %

5.0 MΩ to 50.0 MΩ

0.1 MΩ

5 %

50 MΩ to 500 MΩ

1 MΩ

5 %

0.50 GΩ to 5.00 GΩ

0.01 GΩ

5 %

5.0 GΩ to 10.0 GΩ

0.1 GΩ

5 %

10.0 GΩ to 50.0 GΩ

0.5 GΩ

20 %

50 GΩ to 100 GΩ

5 GΩ

20 %

>100 GΩ

Unspecified

Unspecified

1000 V

<200 kΩ

Unspecified

Unspecified

200 kΩ to 500 kΩ

1 kΩ

5 %

0.50 MΩ to 5.00 MΩ

.01 MΩ

5 %

5.0 MΩ to 50.0 MΩ

0.1 MΩ

5 %

50 MΩ to 500 MΩ

1 MΩ

5 %

0.50 GΩ to 5.00 GΩ

0.01 GΩ

5 %

5.0 GΩ to 20.0 GΩ

0.1 GΩ

5 %

20.0 GΩ to 50.0 GΩ

0.5 GΩ

20 %

50 GΩ to 200 GΩ

5 GΩ

20 %

>200 GΩ

Unspecified

Unspecified

2500 V

<200 kΩ

Unspecified

Unspecified

200 kΩ to 500 kΩ

1 kΩ

5 %

0.50 MΩ to 5.00 MΩ

0.01 MΩ

5 %

5.0 MΩ to 50.0 MΩ

0.1 MΩ

5 %

50 MΩ to 500 MΩ

1 MΩ

5 %

0.50 GΩ to 5.00 GΩ

0.01 GΩ

5 %

5.0 GΩ to 50.0 GΩ

0.1 GΩ

5 %

50 GΩ to 500 GΩ

5 GΩ

20 %

>500 GΩ

Unspecified

Unspecified

Insulation test voltage accuracy: -0 %, +10 % @ 1 mA load current Charging rate for capacitive load: 5 s/μF Discharging rate for capacitive load: 1.5 s/μF

 

Range

Accuracy

Leakage current measurement

1 nA to 2 mA 

±(20 % + 2 nA) 

Capacitance measurement 

0.01 μF to 2.00 μF 

±(15 % rdg + 0.03 μF)

Test voltage for insulation resistance

250 V to 2500 V 

±(3 % + 3 V) 

Warning for energized circuit

Warning range

>30 V 

Timer (F1537 only)

Range

0 to 99 min

 

Resolution

Setting: 1 min

Alert: 1 s

Short circuit current

F1535

>2 mA

F1537

>5 mA

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information